"Z" Lock Flush Wall Partition Systems

CLIN ® “Z” Lock Flush Wall Partition System was designed specifically for life science and pharmaceutical applications that require a flush wall surface with radius corners for ease of cleaning.

The pre-engineered CLIN ® Tongue & Groove partition panels head track consists of a U-shaped prepainted steel track, which is attached to the underside of the ceiling panel system. By sliding the top panel edge up into the head track and dropping it down onto the floor track, the panel is secured into position. The wall panels can be fabricated from various cores and lamination skins to suit various cleanroom applications up to Class 1 classification & GMP requirement.

CLIN ® Wall Partition System is tested and classified by the Malaysian Fire Department as Class ‘O’ material in accordance with British Standard series BS 476 Part 6: 1989 and BS 476 Part 7: 1997.

“A wide range of CLIN ® door sets and single-glazed or double-glazed windows are also available to complement the CLIN ® partition systems.”

 

 Engineered Design

The edges of the panel’s exterior and interior metal faces are formed into a tongue & groove configuration to provide a positive interlock between joining panels. This double tongue & groove joint, when fully engaged, provideds structural continuity and integrity between the adjacent panels compliant to GMP requirement.

 Corrosion Free

Metal skin paint finishes provide the ultimate protection in corrosion resistance against moisture, chemicals and the weather.

 Attractive Finish

High quality skin with pleasing clean finish enhances the appearance of any building or facility.

 Easy Installation

The pre-engineered tongue & groove wall panels are provided in many styles and can be configured to fit any layout. Their simple and fast installation is specially designed to minimize plant disruption. Completed CLIN ® Flush Panel System with a (50m) 2” radius covings create flush corner transitions and seamless wall-to-ceiling and wall-to-floor connections.

45mm Stud Wall Partition Systems

CLIN ® 45mm Stud Wall Partition System is a non-progressive and demountable system that allow easy access of wall panel without disturbing adjacent panels, ceiling or framing Stud Post for minimum contamination to meet the high standards and ever-changing needs of cleanroom applications and customer requirements.

The metal frame of CLIN ® Stud Wall Partition System is made out of durable and corrosion-free extruded aluminium to provide a long lasting and attractive appearance. The wall panels can be fabricated from various cores and lamination skins to suit various cleanroom applications up to Class 1 classification.

CLIN ® Wall Partition System is tested and classified by the Malaysian Fire Department as Class ‘O’ material in accordance with British Standard series BS 476 Part 6: 1989 and BS 476 Part 7: 1997.

“A wide range of CLIN ® door sets and single-glazed or double-glazed windows are also available to complement the CLIN ® partition systems.”

 

 Engineered Design

Sturdy and rigid self-supporting Stud Post system with easy connection of Vertical and Horizontal members to ensure a perfect fit of panels and rigid construction.

 Corrosion Free

Extruded aluminium structure provides the ultimate protection in corrosion resistance against moisture, chemicals and the weather.

 Attractive Finish

High quality skin with pleasing clean finish enhances the appearance of any building or facility.

 Easy Installation

Modular design and pre-fabricated concept facilitates fast and easy installation on site.

Non-progressive design allows you to change individual panels easily or relocate the entire structure.

45mm Wall Partition Systems

CLIN ® 45mm Wall Partition Systems is a non-progressive and demountable system that offers optimum functionality and flexibility in space restraints to meet the high standards and ever-changing needs of cleanroom applications and customer requirements.

The metal frame of CLIN ® Wall Partition System is made out of durable and corrosion-free extruded aluminium to provide a long lasting and attractive appearance. The wall panels can be fabricated from various cores and lamination skins to suit various cleanroom applications up to Class 1 classification.

CLIN ® Wall Partition System is tested and classified by the Malaysian Fire Department as Class ‘O’ material in accordance with British Standard series BS 476 Part 6: 1989 and BS 476 Part 7: 1997.

“A wide range of CLIN ® door sets and are also available to complement the CLIN ® partition systems.”

 

 Engineered Design

Sturdy and rigid framing system ensures a perfect fit of panels and rigid construction.

 Corrosion Free

Extruded aluminium structure provides the ultimate protection in corrosion resistance against moisture, chemicals and the weather.

 Attractive Finish

High quality skin with pleasing clean finish enhances the appearance of any building or facility.

 Easy Installation

Modular design and pre-fabricated concept facilitates fast and easy installation on site.

45mm Flush Wall Partition Systems

CLIN ® Flush Wall Partition System Panel consists of rolled-edge top and bottom steel or aluminium skins bonded to an aluminium honeycomb core for a total thickness of 45mm with aluminium perimeter frame bonded between the skins. Designed specifically for life science and pharmaceutical applications that require a flush wall surface with radius corners which promotes ease cleaning.

The pre-engineered CLIN ® flush partition panels head track consists of a U-shaped prepainted steel track, which is attached to the underside of the ceiling panel system. By sliding the top panel edge can be fabricated from various cores and lamination skins to suit various cleanroom applications up to Class 1 classification & GMP requirement.

CLIN ® Wall Partition System is test and classified by the Malaysian Fire Department as Class ‘O’ material in accordance with British Standard series BS 476 Part 6: 1989 and BS 476 Part 7: 1997.

“A wide range of CLIN ® door sets and single-glazed or double-glazed windows are also available to complement the CLIN ® flush partition systems.”

 

 Engineered Design

Progressive studless wall panel with aluminium perimeter frame edges are tightly engaged to adjoining panels with a fixed aluminium spline. When fully engaged, this spline joint provides structural continuity and integrity between the adjacent panels compliant to GMP requirement.

 Corrosion Free

Extruded aluminium structure provides the ultimate protection in corrosion resistance against moisture, chemicals and the weather.

 Attractive Finish

High quality skin with pleasing clean finish enhances the appearance of any building or facility.

 Easy Installation

The pre-engineered flush wall panels are provided in many styles and can be configured to any layout. Their simple and fast installation is specially designed to minimize plant disruption. Completed CLIN ® Flush Panel System with a (50mm) 2” radius covings create flush corner transistions and seamless wall-to-ceiling and wall-to-floor connections.

The steel profiles and paint finishes provide an easily cleaned, hygienic, low maintenance sterile surface.

6mm & 13mm Wall Partition Systems

CLIN ® 6mm and 13mm Wall Partition Systems are non-progressive and demountable systems that offer optimum functionality and flexibility in space constraints to meet the high standards and ever-changing needs of cleanroom applications and customer requirements.

The metal frame of CLIN ® Wall Partition System is made out of durable and corrosion-free extruded aluminium to provide a long lasting and attractive appearance. The wall panels can be fabricated from various cores and lamination skins to suit various industrial and cleanroom applications.

CLIN ® Wall Partition System is tested and classified by the Malaysian Fire Department as Class “O” material in accordance with British Standard series BS 476 Part 6: 1989 and BS 476 Part 7: 1997.

All wide range of CLIN ® door sets and windows are also available to complement the CLIN ® partition systems.

 

 Engineered Design

Sturdy and rigid framing system ensures a perfect fit of panels and rigid construction.

 Corrosion Free

Extruded aluminium structure provides the ultimate protection in corrosion resistance against moisture, chemicals and weather environments.

 Attractive Finish

High quality skin with pleasing clean finish enhances the appearance of any building or facility.

 Easy Installation

Modular design and pre-fabricated concept facilitates fast and easy installation on site.

Wall Partition System

CLIN ® Wall Partition System offer a non-progressive, demountable system that can easily conform to meet any cleanroom requirements.

CLIN ® panel can be configured from various cores and lamination skins to suit different classes of cleanliness and applications.

We also customize sizes of opening to accommodate pass box, sockets outlets etc on the panel.

 

 Products

Panel cores available:
• Gypsum • Calcium silicate • Paper Honeycomb • Aluminium Honeycomb • Polystyrene (PS) • Polyurethane (PU) • Rockwool

Panel skins available:
• Prepainted steel sheet • Prepainted aluminium sheet • Stainless steel • Vinyl lamination • High pressure laminates (HPL)

 Application

• Up to class 1 cleanroom installation
• Static control environments
• Anti-bacteria grade skin

 Benefits

• Non-progressing & demountable
• Engineered & innovative design for easy installation
• Easy cleaning & pleasing surfaces
• Matching door & window system
• No exposed fastener

 Technical Data

• Tested in accordance with BS and MS standards
• Static control & anti-bacteria surfaces
• Natural anodized & epoxy powder coated finishes
• Standard size 6mm, 13mm, 45mm
• Aluminium accessories
• Epoxy adhesive
• Colorbond prepainted steel

 Variations

• Customised sizes & design
• Opening at factory for ancillary devices
• Various core & skin configurations

 Resources & Articles

CLIN ® "Resources" page is for individuals/companies seeking information on cleanrooms and controlled environments. Find Cleanroom News, Discussion Forums, Cleanroom Cleaning Recommendations, Cleanroom Terminology, Cleanroom Directory, and more.

 Content Disclaimer

Information are contributed by/from different websites and all credit goes to its respective owners/writers/websites/companies and etc, and while we endeavour to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the website or the information, products, services, or related graphics contained on the website for any purpose. Any reliance you place on such information is therefore strictly at your own risk.

In no event will we be liable for any loss or damage including without limitation, indirect or consequential loss or damage, or any loss or damage whatsoever arising from loss of data or profits arising out of, or in connection with, the use of this website.

Through this website you are able to link to other websites which are not under the control of respective owners/writers/websites/companies and etc. We have no control over the nature, content and availability of those sites. The inclusion of any links does not necessarily imply a recommendation or endorse the views expressed within them.

Every effort is made to keep the website up and running smoothly. However, CLIN ® takes no responsibility for, and will not be liable for, the website being temporarily unavailable due to technical issues beyond our control.

We are experienced in Cleanroom Solutions

Call Us for Consultation +6(04) 398 1778

About CLIN

Cleanroom Industries Sdn. Bhd. was founded in 1999 as a pioneer manufacturer in Malaysia specializing in design and manufacture of a full range of cleanroom-related architectural products for cleanroom applications up to Class 1 cleanliness.

Awards & Recognitions

ISO 9001 Malaysia Power Brand Super Excellent Brand Sirim QAS Made in Malaysia Asia Pacific International Honesty Enterprise Keris Award