CLIN
  •   
  •   +6(04) 398 1778
Popular Clean Room Floors

Popular Clean Room Floors

With science and technology advances, the clean room, also called dust free workshop, has become an indispensable working area for electronics factory, medical, food, and other industries. The selection of clean room floors is based on product construction technique, installation and more factors.

Top 4 Popular Clean Room Floor Panels - Common Dust Free Floor Differences

I. Clean Room Raised Floor
The raised access floor is suitable for electronics factory, electromechanical room, constant temperature laboratory, etc. The dust free workshop raised floor is more complicated than the PVC floor, it needs to be equipped with stringers and adjust the beam level or location.

Clean Room Raised Floor Installation
1. Draw lines on the clean ground
2. Assemble the raised floor pedestal and stringer
3. Adjust the stringer level and tighten the screws
4. Laying the raised floor
5. Clean the floor surface after construction is completed

Clean Room Raised Floor Applications
Electronics factory, semiconductor factory, optoelectronic industry, electromechanical room, constant temperature constant room laboratory, and 100-level purification engineering.

II. Clean Room PVC Floor
PVC floor is made of Polyvinyl chloride, which originated in Europe and now is still a popular building material in Europe and North America, it began to enter the Chinese market in the 1980s and has become the basic material for large cities in China. The construction process of this type of floor is relatively simple, just need to clean the ground and then follow the steps to install. PVC flooring is also known as lightweight flooring.

Clean Room PVC Floor Installation
1. Clean the ground, remove the floating and sinking, and locate the laying baseline
2. Lay the copper foil and brushing conductive adhesive
3. Laying PVC floor and rolling it
4. Open 4mm static ground

Clean Room PVC Floor Applications
Electronics factory, semiconductor factory, optoelectronic industry, packaging products, mechanical and electrical room, automobile industry, etc.

III. Clean Room Epoxy Antistatic Self Leveling Floor
Epoxy resin anti-static self-leveling floor roughly has the same function as the clean room epoxy self-leveling floor, the only difference is the former one anti-static.

Clean Room Epoxy Antistatic Self Leveling Floor Installation
1. Substrate treatment: sanding and cleaning the ground, dry and flat floor panels required
2. Bottom coating: conductive coating
3. Laying copper foil: laying horizontally and vertically
4. Medium coating: according to the thickness of the ground, anti-static coating
5. Top coating: anti-static self-leveling flat paint

Clean Room Epoxy Antistatic Self Leveling Floor Applications
Communication equipment manufacturers, chip dust-free manufacturing plants, STM dust-free workshops, optical instruments dust-free workshops, laboratories and other dust-free workshops with high anti-static requirements.

IV. Clean Room Epoxy Self Leveling Floor
Clean room epoxy self-leveling floor has a strong automatic leveling function, you can repair the height difference of the panel so that all the exposed height of the floor can be maintained at the same level and this type of raised flooring is also very resistant to friction.

Clean Room Epoxy Self Leveling Floor Installation
1. Polish the floor, clean and vacuum
2. Brushing a closed bottom paint
3. Middle coating
4. Grinding and vacuuming
5. Self leveling

Clean Room Epoxy Self Leveling Floor Applications
Electronics factory, electrical appliance factory, food factory, cosmetics factory, packaging factory, textile factory, garment factory, etc.

How to Select the Clean Room Access Floor?

Cleanliness Requirements
The purified production environment has become an important condition for the development of modern science and modern industry. Clean rooms can be used to ensure cleanliness, but different applications have different cleanliness requirements, some have high cleanliness requirements, such as large-scale integrated circuits, ultra-large-scale integrated circuits, etc.; some requirements are second, such as semiconductor manufacturing, gyroscopes, etc.; other cleanliness can be lower, such as electronic components, optical machines. This will also affect the clean room access floor solution.

Mechanical and Chemical Properties of Flooring
The performance of clean room flooring should be taken into consideration, including wear resistance, pressure resistance, impact resistance, acid and alkali resistance and solvent resistance. Choose the right floor that conforms to the workshop requirements.

Floor Location and Environment
According to the floor location, underfloor or on the ground, it is necessary to determine whether moisture-proof treatment is needed or whether to select a special moisture-proof floor. The clean room raised floor also need to look harmonious with the existing environment from colors, lighting and more.

Safety Requirements
If the floor is in an oil-stained environment or on a ramp, it is necessary to choose a non-skid clean room floor.

 Resources & Articles

CLIN ® "Resources" page is for individuals/companies seeking information on cleanrooms and controlled environments. Find Cleanroom News, Discussion Forums, Cleanroom Cleaning Recommendations, Cleanroom Terminology, Cleanroom Directory, and more.

 Content Disclaimer

Information are contributed by/from different websites and all credit goes to its respective owners/writers/websites/companies and etc, and while we endeavour to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the website or the information, products, services, or related graphics contained on the website for any purpose. Any reliance you place on such information is therefore strictly at your own risk.

In no event will we be liable for any loss or damage including without limitation, indirect or consequential loss or damage, or any loss or damage whatsoever arising from loss of data or profits arising out of, or in connection with, the use of this website.

Through this website you are able to link to other websites which are not under the control of respective owners/writers/websites/companies and etc. We have no control over the nature, content and availability of those sites. The inclusion of any links does not necessarily imply a recommendation or endorse the views expressed within them.

Every effort is made to keep the website up and running smoothly. However, CLIN ® takes no responsibility for, and will not be liable for, the website being temporarily unavailable due to technical issues beyond our control.

We are experienced in Cleanroom Solutions

Call Us for Consultation +6(04) 398 1778

About CLIN

Cleanroom Industries Sdn. Bhd. was founded in 1999 as a pioneer manufacturer in Malaysia specializing in design and manufacture of a full range of cleanroom-related architectural products for cleanroom applications up to Class 1 cleanliness.

Awards & Recognitions

ISO 9001 Malaysia Power Brand Super Excellent Brand Sirim QAS Made in Malaysia Asia Pacific International Honesty Enterprise Keris Award