Cleanrooms are typically used in scientific research and manufacturing to provide a controlled environment for handling sensitive components and samples. Cleanrooms are constructed in a way to minimize particles from being introduced, generated or retained inside the room. Depending on the cleanroom classification and application, the gowning procedure may vary. However, the following sequence is basically the same.

The higher the level of cleanliness, the lower the particles inside the room. Cleanrooms are typically classified as ISO 5 or ISO 6. Click here to view Cleanroom Classification list.

The largest percent of contributors to contamination within a clean room are people. Even the cleanest of people are naturally contaminated. Our bodies are natural host to unwanted bacteria, along with the shedding of skin cells, hair and exhale of bio-organisms. A well designed gowning room and strict gowning procedure must be followed in order to maintain a cleanliness classification. We will be covering the procedures personnel should follow to get cleanroom ready and some of the Cleatech gowning equipment that supports the gowning protocol.

What Industries Require a Cleanroom?
Industries such as Pharmaceutical, Food, Microbiology, Semiconductor, Medical, and Manufacturing require personnel to follow a gowning procedure.

Best Practices for Cleanroom Gowning
Follow the following steps to control contamination when donning and removing cleanroom apparel.

Cleanroom Gowning Procedure Checklist

Do’s

  • Use sterile gloves for cleanroom and aseptic processing
  • Dry hands completely before gloves are donned
  • Cover dominant hand first
  • Use wall mount dispenser for easy access and less movement

Dont’s

  • Never let clean surfaces contact dirty one.
  • Never touch cleaned garment without washing your hands.
  • Never allow garments to touch the floor.
  • Never use powder gloves.
  • Never Wear jewelry, fingernail polish or cosmetics.
  • Never touch exposed skin with a gloved hand.

Top-Down Donning Sequence

  • Start by washing your hands thoroughly.
  • Take a few steps over a tacky mat to remove excess dirt.
  • Don disposable booties (shoe cover). The cover should have laces.
  • If required, put on donning gloves.
  • Apply bouffant (beard covers for users with facial hair).
  • You can now enter the gowning area.
  • Remove hood from cleanroom bag, make sure to only touch the inside of the hood. It should completely cover your bouffant.
  • Apply face mask. Adjust the nosepiece to fit your face.
  • Remove coverall from cleanroom bag by holding the coverall inside the neck part.
  • Don cleanroom booties.
  • Don goggles or Shield.
  • Put on cleanroom gloves, gloves should be rolled over coverall sleeves.
  • Walk over a cleanroom tack mat to prevent contamination before entering the cleanroom area.
  • That completes our gowning procedure. Following these steps, each and every time will help prevent contamination inside the cleanroom.
 Resources & Articles

CLIN ® "Resources" page is for individuals/companies seeking information on cleanrooms and controlled environments. Find Cleanroom News, Discussion Forums, Cleanroom Cleaning Recommendations, Cleanroom Terminology, Cleanroom Directory, and more.

 Content Disclaimer

Information are contributed by/from different websites and all credit goes to its respective owners/writers/websites/companies and etc, and while we endeavour to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the website or the information, products, services, or related graphics contained on the website for any purpose. Any reliance you place on such information is therefore strictly at your own risk.

In no event will we be liable for any loss or damage including without limitation, indirect or consequential loss or damage, or any loss or damage whatsoever arising from loss of data or profits arising out of, or in connection with, the use of this website.

Through this website you are able to link to other websites which are not under the control of respective owners/writers/websites/companies and etc. We have no control over the nature, content and availability of those sites. The inclusion of any links does not necessarily imply a recommendation or endorse the views expressed within them.

Every effort is made to keep the website up and running smoothly. However, CLIN ® takes no responsibility for, and will not be liable for, the website being temporarily unavailable due to technical issues beyond our control.

We are experienced in Cleanroom Solutions

Call Us for Consultation +6(04) 398 1778

About CLIN

Cleanroom Industries Sdn. Bhd. was founded in 1999 as a pioneer manufacturer in Malaysia specializing in design and manufacture of a full range of cleanroom-related architectural products for cleanroom applications up to Class 1 cleanliness.

Awards & Recognitions

ISO 9001 Malaysia Power Brand Super Excellent Brand Sirim QAS Made in Malaysia Asia Pacific International Honesty Enterprise Keris Award