CLIN
  •   
  •   +6(04) 398 1778
Automotive Cleanroom Design

Automotive Cleanroom Design

Your cleanroom doors are the most vulnerable part of the cleanroom. As the most likely place for particles and contamination to enter your controlled cleanroom environment, it’s important to choose cleanroom doors that are secure, reliable, and contaminant-free. There are many factors to consider when choosing cleanroom doors for your facility. The first consideration you’ll need to make is the type of cleanroom doors that will best serve your automotive cleanroom’s needs.

 TYPES OF CLEANROOM DOORS
Cleanroom doors typically come in two main varieties: swinging, sliding, and high-speed roll-up doors. Let’s take a look at the difference between them and the advantages they can offer your automotive cleanroom application.

 SWINGING CLEANROOM DOORS
Swinging cleanroom doors are attached to hinges on one side of the cleanroom door frame. They swing out of the cleanroom, or in, or both. These doors are designed to close flush with the rest of the wall panel with an airtight seal. They can be installed at different heights and widths as your application demands.

A disadvantage of swinging cleanroom doors is they take up space in your cleanroom, as there needs to be room for the door to swing. Also, the movement of the door can sometimes create turbulent air within the cleanroom. In some applications this could disrupt the airflow pattern and spell trouble for contamination-sensitive processes.

SLIDING CLEANROOM DOORS
Sliding doors are attached on tracks at the top and bottom of the threshold. The tracks can be built seamlessly into the floor and ceiling panels so no particles can get inside. A major advantage of sliding cleanroom doors is that they don’t take up as much space as swinging doors. They slide into wall panels or fit along the wall with a slim profile, saving valuable floor space for your operations.

Sliding doors can also be programmed to open and close automatically, which improves efficiency in high traffic areas. The automatic option saves your employees from having to touch handles to operate the door, which works well in applications where employees need to carry materials or move between rooms hands-free. Be aware that sliding cleanroom doors usually require electronic access to open and close. If there’s a power failure, you’ll need to have a back up system in place to operate the door.

 HIGH-SPEED ROLL-UP DOORS
High-speed roll-up doors are an increasingly popular option for cleanrooms in many industries. When in operation, the fabric “curtain” rolls up and is conveniently stored in a space-efficient head assembly at the ceiling, saving valuable wall space compared to other types of cleanroom doors. These doors are able to maintain a high-quality seal so as to retain clean air within the cleanroom and keep out contaminating particles. They can be made using non-porous, non-particle-shedding, and antimicrobial materials to withstand your cleanroom cleaning protocol and protect the controlled environment.

High-speed roll-up cleanroom doors can be built to a custom height and width to accommodate non-standard equipment and products. The new generation of roll-up doors can be operated at speeds as high as 100 in/s, so you can open and close the door with minimum disruption to cleanroom activities.

 CLEANROOM PASS-THROUGHS
Cleanroom pass-throughs are cabinets installed in the walls of your automotive cleanroom for the transfer of objects in and out of the cleanroom environment. Pass-throughs have swinging doors attached at both ends where items can be placed or removed.

When properly installed and sealed, cleanroom pass-throughs can improve productivity and safety, and reduce the need for traffic to enter and exit through cleanroom doors which preserves the cleanroom environment. This also lowers your operating costs, as you’re not wasting the energy to filter and regulate the air lost when opening and closing a door, versus the smaller volume of a cleanroom pass-through.

CHOOSING CLEANROOM DOORS PASS-THROUGHS
When designing your automotive cleanroom, it’s important to choose the right cleanroom doors and pass-throughs that will offer the best performance for your application.

Your automotive cleanroom doors and pass-throughs…

  • Must be airtight and flush with the walls. An airtight seal prevents particles from settling in the hinges, around the edges or any part of the door or pass-through itself. This helps to minimize the transference of unfiltered air and reduce the risk of contamination in your automotive cleanroom.
  • Must be easily integrated with your modular wall panels. Should also be able to accommodate the people, equipment, and products moving in and out of the cleanroom, but not too large that you waste extra energy by releasing filtered and regulated air out of the cleanroom unnecessarily.
  • Must be sturdy and impact-resistant. The ideal cleanroom doors will be strong enough to withstand consistent use, yet light enough to be easily operated. They should not be damaged easily if a piece of equipment or employee bumps into them.
  • Must be able to withstand cleaning. Your cleanroom doors should be made of a material that won’t corrode or shed particles into your controlled environment when cleaned.
  • Must be antistatic. Cleanroom doors should not allow the buildup of static electricity which could cause damage to your processes or people, or attract contaminating particles.
  • Must be able to lock. Having cleanroom doors with a secure locking mechanism is necessary to maintain a closed environment to protect interior operations, as well as to secure the room when it’s not in use. The locking mechanism must be able to function if electricity is interrupted — you don’t want to risk not being able to close the room, or worse, trapping personnel inside if there’s an unexpected outage.
 Resources & Articles

CLIN ® "Resources" page is for individuals/companies seeking information on cleanrooms and controlled environments. Find Cleanroom News, Discussion Forums, Cleanroom Cleaning Recommendations, Cleanroom Terminology, Cleanroom Directory, and more.

 Content Disclaimer

Information are contributed by/from different websites and all credit goes to its respective owners/writers/websites/companies and etc, and while we endeavour to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the website or the information, products, services, or related graphics contained on the website for any purpose. Any reliance you place on such information is therefore strictly at your own risk.

In no event will we be liable for any loss or damage including without limitation, indirect or consequential loss or damage, or any loss or damage whatsoever arising from loss of data or profits arising out of, or in connection with, the use of this website.

Through this website you are able to link to other websites which are not under the control of respective owners/writers/websites/companies and etc. We have no control over the nature, content and availability of those sites. The inclusion of any links does not necessarily imply a recommendation or endorse the views expressed within them.

Every effort is made to keep the website up and running smoothly. However, CLIN ® takes no responsibility for, and will not be liable for, the website being temporarily unavailable due to technical issues beyond our control.

We are experienced in Cleanroom Solutions

Call Us for Consultation +6(04) 398 1778

About CLIN

Cleanroom Industries Sdn. Bhd. was founded in 1999 as a pioneer manufacturer in Malaysia specializing in design and manufacture of a full range of cleanroom-related architectural products for cleanroom applications up to Class 1 cleanliness.

Awards & Recognitions

ISO 9001 Malaysia Power Brand Super Excellent Brand Sirim QAS Made in Malaysia Asia Pacific International Honesty Enterprise Keris Award